The ATC-300+ is a comprehensive and multifunctional microprocessor-based ATS controller. It is a compact and self-contained panel-mounted device that is designed to replace traditional relay and solid-state logic panels. The ATC-300+ Controller provides programmed flexibility to address the needs of any system. It operates from all system voltages between 120 to 600V, single-phase and three-phase at 50 or 60 Hz. In addition, a period of no control power is provided. The controller monitors the condition of the three-phase line-to-line voltage and frequency of Source 1 and Source 2 power sources and can be programmed for single-phase operation. The ATC-300+ Controller provides the intelligence to ensure that the ATS operates properly through a series of programmed sensing and timing functions.

    Want to learn more?

    REQUEST A PRICE

    A member of our Sales Team will be in touch to support your enquiry.
    By submitting this form, you consent to receive future marketing communications from us. You have read and agree to our Terms & Conditions and Privacy Policy, and can opt-out at any time.

      Want to learn more?

      Send an Enquiry

      A member of our Sales Team will be in touch to support your enquiry.
      By submitting this form, you consent to receive future marketing communications from us. You have read and agree to our Terms & Conditions and Privacy Policy, and can opt-out at any time.
      • 120 to 600V, single phase and three phase @ 50/60 Hz
        Rating Range
      • Switch application dependent
        Transfer Type
      • More specifications

      Benefits & Features

      Product Features
      • Auxiliary relay contacts:
        • Source 1 present 2NO and 2NC
        • Source 2 present 2NO and 2NC
      • Source 1 and source 2 sensing:
        • Undervoltage / underfrequency
        • Overvoltage / overfrequency
        • Three-phase rotation protection
        • Three-phase voltage unbalance/loss
      • Pre-transfer signal contacts 1NO and 1NC
      • Go to emergency (Source 2)
      • Seven field-programmable time delays
      • LCD-based display for programming, system diagnostic and help message display
      • Mimic diagram with source available and connected LED indication
      • Time-stamped history log
      • System test pushbutton
      • Programmable plant exercise (off, daily, 7,14 and 28 day) interval selectable run time 0-600 minutes no load/load with fail-safe
      • Integral overcurrent protection (optional)
      • In-phase transition
      • Stainless steel cover for controller (optional)
      • Communications via RS-232 or Modbus through an integrated RS-485 port (optional)

      specifications

      Technical Summary
      Rating Range 120 to 600V, single phase and three phase @ 50/60 Hz
      Transfer Type Switch application dependent
      Switch Type Switch application dependent
      ATC Controller Specifications
      Input Control Voltage 65 to 145 Vac 50/60 hZ
      Voltage Measurements of Utility Source 1 VAB Source 2 VAB<br>Source 1 VAC Source 2 VBC<br>Source 1 VCA Source 2 VCA
      Voltage Measurement Range 0 to 790 VAC rms (50/60 Hz)
      Voltage Measurement Accuracy +/-2% of nominal input voltage
      Frequency Measurements Of Source 1 and Source 2
      Frequency Measurement Range 40 Hz to 70 Hz
      Frequency Measurement Accuracy +/- 0.1 Hz
      Undervoltage Dropout 50% to 90% of nominal voltage
      Undervoltage Pickup (Dropout +2%) to 99% of the nominal system voltage
      Underfrequency Dropout Range 90 to 97% of the nominal system frequency
      Underfrequency Pickup Range (Dropout +1 Hz) to 99% of the nominal system frequency
      Overfrequency Dropout Range 103 to 110% of the nominal system frequency
      Overfrequency Pickup Range 101% to (dropout - 1 Hz) of the nominal system frequency
      Operating Temperature Range -20 to 70 degree C (-4 to +158 degree F)
      Storage Temperature Range -30 to 85 degree C (-22 to +185 degree F)
      Operating Humidity 0 to 95% relative humidity (noncondensing)
      Operating Environment Resistant to ammonia, methane, nitrogen,hydrogen and hydrocarbons
      Generator Start Relay 5A, 1/6 hp @ 250 Vac Vac 5A @ 30 Vdc with a 150W maximum load
      K1, K2 Relays <br>10A, 1-3 hp @ 250 Vac</br><br>10A@30 Vdc</br>
      Applicable Testing UL-recognized component<br>Meets intent of UL 991 & UL 1008<br>Meets IEC 1000-4-2, 1000-4-3, 1000-4-4
      Applicable Testing Continued 1000-4-5, 1000-4-6, 1000-4-11<br>CISPR 11, Class A<br>FCC Part 15, Class A<br>CSS 22.2-178
      Enclosure Compatibility NEMA 1, NEMA 3R and NEMA 12<br>UV-resistant ATC-300+ faceplate

      Product specifications, standard and optional equipment may vary depending on stock availability. For more information or to verify specific product details, please get in touch with one of our sales representatives.