      Benefits & Features

      Cat Generator Set Package
      • Cat generator set packages have been fully prototype tested
      • Accepts 100% block load in one step and meets NFPA 110 loading requirements
      • Conform to ISO 8528-5 steady state and transient response requirements
      Cat Diesel Engine
      • Reliable, rugged, durable design
      • Field-proven in thousands of applications worldwide
      • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
      M-Frame Alternator
      • Superior motor starting capability minimizes need for oversizing alternator
      • Designed to match performance and output characteristics of Cat diesel engines
      • Robust Class H insulation
      GCCP 1.2 Control Panel
      • User-friendly interface and navigation
      • Scalable system to meet a wide range of installation requirement
      • Expansion modules and site-specific programming for specific customer requirements
      Cooling System
      • Designed to operate in standard ambient temperatures up to 55°C (131°F)
      • Contact your Cat Dealer for specific ambient and altitude capabilities
      Certifications
      • UL 2200 Listed
      • ULC Certification Available
      One Safe Source
      • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
      • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
      • Each generator set package is tested before leaving the Caterpillar facility
      • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
      Worldwide Product Support
      • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
      • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

      specifications

      Generator Set Specifications
      Maximum Rating 50 ekW
      Minimum Rating 50 ekW
      Emissions/Fuel Strategy U.S. EPA Cert., Tier 3, SCAQMD Compliant
      Voltage 208 to 600 Volts
      Frequency 60 Hz
      Speed 1800 rpm
      Duty Cycle Standby
      Engine Specifications
      Engine Model C4.4, In-line 4, 4-cycle diesel
      Bore 105 mm
      Stroke 127 mm
      Displacement 4.4 l
      Compression Ratio 18.2:1
      Aspiration Turbocharged
      Fuel System Common Rail
      Governor Type Mechanical, ADEM™A4
      Generator Set Dimensions
      Length - Maximum 1962 mm
      Width - Maximum 1100 mm
      Height - Maximum 1220 mm
      Dry Weight - Genset (maximum) 932 kg
      Certificates
      • IBC seismic and wind Certifications
      Air Inlet System
      • Air cleaner
      • Cartridge type air filter
      Circuit breakers
      • Second circuit breaker box
      • Power terminal strip
      • Breakers (100% UL rated)
      • 3-Pole 100% rated
      Charging System
      • NFPA battery charger UL10A 120VAC
      Control Panel
      • GCCP 1.2 Control panel
      Exhaust System
      • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
      Fuel System
      • Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
      Cooling System
      • Fan drive, battery charging alternator drive
      • Caterpillar extended life coolant
      • Radiator and cooling fan with guards
      • Coolant drain line with valve
      • Radiator stone guard
      Control Panels
      • NFPA110 bundle includes:
      • WCA1 Low coolant temperature alarm
      • FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
      • WSS1 Low coolant level shut down
      • PBC10NU NFPA battery charger
      • Oil temperature gauge and sender
      • PAA1 Panel mounted audible alarm
      • A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
      • Audible alarm
      • Remote E-stop button
      • Ground fault relay
      • Discrete I/O module
      • Remote annunciator module
      • Volt free contacts genset run and common alarm
      • Fuel level reading
      • Protective devices:
      • Low coolant temperature alarm
      • Low coolant level shutdown
      • Overload shutdown via breaker
      Generator
      • 12 Leads
      Governing System
      • Mechanical and electrical governing system - model dependent
      Lube System
      • Lubricating oil
      • Oil drain line with valve
      General
      • Engine and alternator pre-paint, Caterpillar yellow
      Starting/Charging System
      • Batteries
      • 24V battery with rack and cables
      Certificates
      • IBC seismic and wind Certifications
      Air Inlet System
      • Cartridge type air filter
      Alternator System
      • R Frame auxilliary winding
      Charging System
      • NFPA battery charger UL10A 120VAC
      Circuit breakers
      • Breakers (100% UL rated)
      • Power terminal strip
      • 3-Pole 100% rated
      • Second circuit breaker box
      Control Panels
      • Volt free contacts genset run and common alarm
      • Oil temperature gauge and sender
      • Remote E-stop button
      • Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
      • Audible alarm
      • Remote annunciator module
      • Discrete I/O module
      • NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
      • Ground fault relay
      Cooling System
      • Radiator transition flange
      Enclosures
      • External emergency stop
      • Sound attenuated enclosure, Level 2
      • Panel viewing window
      Exhaust System
      • 10, 25 and 35 dBA silencer systems
      • Overhead silencer mounting kit
      Fuel System
      • 5 Gallon spill containment
      • 209 and 394 gallon sub-base fuel tanks
      • Tank riser
      • Emergency vent pipe
      • 5 Gallon fill containment
      Heating Elements
      • Coolant heater
      • Wiring for canopy space heater
      • Battery heater
      • Lube oil sump heater
      • Anti-condensation heater
      • Wiring for canopy space heater
      • Jacket water heater
      Generators
      • Permanent magnet excitation (PMG) generator
      • Permanent magnet excitation (PMG) generator
      Mounting System
      • Seismic vibration isolators
      Tests
      • 4 Hour factory test
      • PGS Test report @ 1.0 power factor
      • PGS Test report @ 0.8 power factor
      • Generator test report