      Benefits & Features

      Cat Generator Set Package
      • Cat generator set packages have been fully prototype tested
      • Accepts 100% block load in one step and meets NFPA 110 loading requirements
      • Conform to ISO 8528-5 steady state and transient response requirements
      A-Frame Alternator
      • Superior motor starting capability minimizes need for oversizing alternator
      • Designed to match performance and output characteristics of Cat diesel engines
      • Robust Class H insulation
      Cat Diesel Engine
      • Reliable, rugged, durable design
      • Field-proven in thousands of applications worldwide
      • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
      GCCP1.3 Control Panel
      • User-friendly interface and navigation
      • Scalable system to meet a wide range of installation requirement
      • Expansion modules and site-specific programming for specific customer requirements
      Cooling System
      • Designed to operate in standard ambient temperatures up to 55°C (131°F)
      • Contact your Cat Dealer for specific ambient and altitude capabilities
      Generator Features
      • Matched to the performance and output characteristics of Cat engines
      • Industry leading mechanical and electrical design
      • Industry leading motor starting capabilities
      • High Efficiency
      Certifications

      The generator set meets transient response and block loading steps as per ISO 8528-5.

      One Safe Source
      • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
      • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
      • Each generator set package is tested before leaving the Caterpillar facility
      • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
      Worldwide Product Support
      • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
      • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

      specifications

      Generator Set Specifications
      Maximum Rating 300 kVA
      Minimum Rating 300 kVA
      Emissions/Fuel Strategy Non-Certified
      Voltage 200 to 400 Volts
      Frequency 50 Hz
      Speed 1500 rpm
      Duty Cycle Standby, Prime
      Engine Specifications
      Engine Model C9 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
      Bore 112 mm
      Stroke 149 mm
      Displacement 8.8 l
      Compression Ratio 16.1:1
      Aspiration Air to Air Aftercooled
      Fuel System Hydraulic electronic unit injection
      Governor Type Adem™A4
      Generator Set Dimensions
      Length - Maximum 3988 mm
      Width - Maximum 1207 mm
      Height - Maximum 1867 mm
      Air Inlet System
      • Air cleaner, light duty with disposable paper filter
      Control Panels
      • GCCP 1.3
      Cooling System
      • Caterpillar extended life coolant
      • Fan drive, battery charging alternator drive
      • Radiator and cooling fan with guard
      • Coolant drain line with valve
      Exhaust System
      • Stainless steel exhaust flex, gaskets, rain cap & SAE exhaust flange for customer use - shipped loose
      Fuel System
      • Base, formed steel with single wall integral 8-hour fuel tank
      • Standard open set fuel tank/base supplied
      Generators and Generator Attachments
      • IP23 Protection
      • 12 Leads
      • Power centre, IP22
      • Mandatory option circuit breaker, IEC, 3 pole mounted in power centre
      • Segregated low voltage (AC/DC) wiring panel
      • Voltage regulator (single phase sensing)
      Governing System
      • Cat electronic governor (ADEM A4)
      Lube System
      • Oil cooler
      • Oil drain valves
      • Lubricating oil
      Mounting System
      • Includes lifting provisions and termination points for coolant and lube oil drain lines
      • Captive linear vibration isolators between base and engine-generator
      Starting / Charging System
      • 24V battery with rack and cables
      General
      • Engine and alternator re-paint, Caterpillar yellow
      Certifications
      • Global Certification for CIS
      • European Certificate for Conformance
      Air inlet system
      • Single element air cleaner
      Circuit breakers
      • 4 Pole (IEC-100% rated) Circuit breaker upgrades: 400, 630, 800 and 100 amps
      Control Panels
      • Control panel Options: Volt free contacts ; Local alarm horn ; Oil temperature displays
      • Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; overload shutdown via breaker ; Low fuel level shutdown ; Low fuel level alarm ; Fuel level sensor
      Cooling System
      • Radiator duct flange
      • Low coolant temperature alarm
      Enclosures
      • Sound attenuated enclosure
      • High ambient sound attenuated enclosure
      Exhaust System
      • 6 inch flange
      • 5 and 6 inch elbow kits
      • Mufflers - End in/end out; 10 dBA or 25 dBA attenuation
      • 5 - 6 inch flange adaptor
      Fuel System
      • Integral dual wall fuel tank base
      Generators and Attachments
      • Permanent magnet excitation (PMG) generator
      • Oversize, AREP, CIP generators
      Mounting System
      • Narrow skid base
      Starting / Charging System
      • Battery disconnet switch
      • Jacket water heater
      • 5 Amp single Battery charger