      Benefits & Features

      Cat Generator Set Package
      • Cat generator set packages have been fully prototype tested
      • Accepts 100% block load in one step and meets NFPA 110 loading requirements
      • Conform to ISO 8528-5 steady state and transient response requirements
      Cat Diesel Engine
      • Reliable, rugged, durable design
      • Field-proven in thousands of applications worldwide
      • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
      M-Frame Alternator
      • Superior motor starting capability minimizes need for oversizing alternator
      • Designed to match performance and output characteristics of Cat diesel engines
      • Robust Class H insulation
      GCCP 1.3 Control Panel
      • User-friendly interface and navigation
      • Scalable system to meet a wide range of installation requirement
      • Expansion modules and site-specific programming for specific customer requirements
      • Image may not be a representative of actual product
      Cooling System
      • Designed to operate in standard ambient temperatures up to 55°C (131°F)
      • Contact your Cat Dealer for specific ambient and altitude capabilities
      Certifications

      Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S℠ program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products

      One Safe Source
      • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
      • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
      • Each generator set package is tested before leaving the Caterpillar facility
      • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
      World Wide Product Support
      • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
      • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

      specifications

      Generator Set Specifications
      Maximum Rating 65.0 kVA
      Minimum Rating 24.0 kVA
      Emissions/Fuel Strategy EU Stage II R96/EUIIIa
      Voltage 110 to 480 Volts
      Frequency 50 Hz
      Speed 1500 rpm
      Duty Cycle Standby, Prime
      Engine Specifications
      Engine Model Cat® C3.3
      Bore 105 mm
      Stroke 127 mm
      Displacement 3.3 l
      Compression Ratio 17.25:1, 19.25:1
      Aspiration Turbocharged
      Fuel System Direct Injection
      Governor Type Mechanical
      Generator Set Dimensions
      Length - Maximum 1115 mm
      Width - Maximum 970 mm
      Height - Maximum 1361 mm
      Air Inlet System
      • Air cleaner; light duty with disposable element
      Control Panel
      • GCCP 1.3
      Cooling System
      • Coolant drain line with valve
      • Radiator and cooling fan with guards
      • Caterpillar extended life coolant
      • Fan drive, battery charging alternator drive
      Exhaust System
      • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
      Fuel System
      • Standard open set fuel tank/base supplied
      • Base, formed steel with single wall integral 8-hour fuel tank
      Generators and Generator Attachments
      • Voltage regulator (single phase sensing)
      • Tower panel, IP22, bottom cable entry
      • Circuit breaker, IEC, 3 pole, mounted in tower panel
      • IP23 Protection
      • Segregated low voltage (AC/DC) wiring panel
      Governing System
      • Mechanical and electrical governing system - model dependant
      Generators and attachments
      • 12 Leads
      Lube System
      • Lubricating oil
      • Oil drain line with valve
      Mounting System
      • Captive linear vibration isolators between base and engine-generator
      • Termination points for coolant and lube oil drain lines
      • Includes lifting provision and drag points
      Starting / Charging System
      • 12V Battery with rack & cables
      General
      • Engine and alternator pre-paint, Caterpillar yellow
      Alternator System
      • R Frame auxilliary winding
      • Anti-condensation heater
      • LC Frame alternator with coastal protection
      • LC Frame alternator
      • Permanent magnet excitation (PMG)
      Circuit breakers
      • Padlockable breaker device
      • 4 Pole Circuit breaker to 250A
      Control Panels
      • GCCP 1.3
      Control Panel Options
      • Emergency stop with key
      Cooling System
      • Low coolant level shutdown
      • Coolant heater
      • Low coolant temperature alarm
      Certifications
      • Global Certification for CIS
      • European upgrade to STD set for "CE"
      Enclosures
      • Sound attenuated level 1 enclosure (GALV)
      • CEE for sockets for enclosure
      • Sound attenuated level 2 enclosure CE
      • Rental pack (CAE only)
      • Socket blanking plate
      Fuel System
      • High fuel level alarm
      • Open set narrow tankbase
      • Compact skidbase for open sets
      • Low fuel level shutdown
      • Low fuel level alarm
      • Skidbase for CALG enclosure sets
      • Bunded fuel tank
      Mounting Options
      • Battery removal
      • Residential silencer
      • Silencer installation kit
      • External single point lift - enclosure
      • Electronic governor
      Special Packing Inspections
      • PGS Test report @ 0.8 power factor
      • PGS Test report @ 1.0 power factor
      General
      • Packing case - compact set
      • Packing case - canopied set

      Product specifications, standard and optional equipment may vary depending on stock availability. For more information or to verify specific product details, please get in touch with one of our sales representatives.

      Request Price Enquire Now