3516C (HD) CI/D2 Hazardous Location

Overview

Cat 3500 offshore generator sets are specifically designed for drilling and production operations offshore. Decades of experience powering offshore vessels and platforms make have evolved into a product that offers proven performance, low emissions, high durability, and low owning and operating costs. Cat generator sets are backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty. Cat 3516C (HD) Class I/ Division 2 offshore generator set ratings: 2100 ekW (2963 bhp) @ 60 Hz (1800 rpm).

Image shown may not reflect actual package.
Enquire
Engine Specifications
Minimum Rating2100ekW
Maximum Rating2100ekW
EmissionsEPA Tier 2, IMO Tier II
Engine ControlADEM A4
Bore170mm
Weight17500kg
Displacement78l
Fuel SystemEUI
Stroke215mm
AspirationDual Turbocharged-Aftercooled
Dimensions
Length6705mm
Height2535mm
Width1986mm
Capacity for Liquids
Lube Oil System - Refill405l
Cooling System - Engine234.7l
AIR INLET SYSTEM
Aftercooler core, corrosion resistant (air side)
Air cleaner, regular duty with service indicators
Dual turbochargers, rear mounted
CONTROL SYSTEM
Dual Caterpillar A4 electronic engine control with electronic unit injector fuel system and rigid wiring harness.
24 VDC (less than 10A) to be provided by customer at Power Distribution Panel to power engine electrical system.
COOLING SYSTEM
Jacket water (JW) engine cooling and two-stage jacket water/separate circuit (SCAC) charge air cooling
To ensure compliance in use, radiators or heat exchangers must be capable of rejecting sufficient heat to allow proper engine operation at worst site conditions.
The radiator or heat exchanger must supply 48C (118 F)
SCAC cooling water to the aftercooler inlet of at least 200 gal/min at ambient temperature of 30C and at site conditions (including altitude considerations)
EXHAUST SYSTEM
Dry gas-tight exhaust manifolds with heat shields, dual turbochargers with water-cooled bearings and heat shields.
Exhaust outlet: 305 mm (12 in) round flanged outlet, vertical orientation
FLYWHEELS & FLYWHEEL HOUSINGS
Flywheel, SAE No. 00, 183 teeth Flywheel housing, SAE No. 00
Flywheel housing, SAE No. 00
SAE standard rotation
FUEL SYSTEM
Duplex Fuel filter, LH service. Simplex fuel filter, RH service
Fuel transfer pump
Fuel priming pump, RH
Electronically Controlled Unit Injectors
Customer connection located at lower right front of engine
SOLAS shielding
INSTRUMENTATION
Engine mounted instrument panel with four position switch, over speed shutdown notification light, emergency stop notification light, graphical display unit for analog or digital display of: oil and fuel pressure, oil and fuel filter differential, system DC voltage, exhaust and water temperature, air inlet restriction, service meter, engine speed, fuel consumption (total and instantaneous)
LUBE SYSTEM
Top mounted crankcase breather, RH oil filter, RH oil filler, gear type oil pump, deep sump oil pan, recommended use of Caterpillar Diesel Engine Oil 10W30 or 15W40
MOUNTING SYSTEM
Mounting rails and isolation system based on customer request
ELECTRICAL SYSTEM
MCS certified Class I / Divison 2
Low Smoke Zero Halogen Wiring Harness
PROTECTION SYSTEM
A-III Electronic Monitoring System provides customer programmable engine de-ration strategies to protect against adverse operating conditions
Emergency stop push button (located in Electronic Instrument Panel) Safety shutoff protection for oil pressure and water temperature, over speed protection
HAZARDOUS LOCATION
Only electrical system is hazardous environment certified
NEC 500 Class I Division 2 for gas groups C and D
Temperature class is T3 for ambient temperatures from -10 C to 50 C
Class I/ Division 2 CMPD
GENERATOR AND GENERATOR ATTACHMENTS
Class I / Division 2 designed to customer's specifications
Insulation for harsh environment protection
Custom Packaging
For any petroleum application, trust Caterpillar to meet your project needs with custom factory generator sets and mechanical packages. Cat engines, generators, controls, radiators, and transmissions can be custom designed and matched in collaboration with our local dealers to create unique solutions. Custom packages are globally supported and are covered by a one year warranty after startup.
Product Support Offered Through the Global Cat Dealer Network
- More than 2,200 dealer outlets - Cat factory-trained dealer technicians service every aspect of your Cat petroleum product - Worldwide parts availability, service, and warranty - Preventive maintenance agreements available for repairbefore- failure opti
Over 80 Years of Engine Manufacturing Experience
Ownership of these manufacturing processes enables Caterpillar to produce high quality, dependable products.
Over 80 Years of Engine Manufacturing Experience
Ownership of these manufacturing processes enables Caterpillar to produce high quality, dependable products.
Web Site
For all your petroleum power requirements, visit www.catoilandgasinfo.com.
Web Site
For all your petroleum power requirements, visit www.catoilandgasinfo.com.
Specifications
Engine Specifications
Minimum Rating2100ekW
Maximum Rating2100ekW
EmissionsEPA Tier 2, IMO Tier II
Engine ControlADEM A4
Bore170mm
Weight17500kg
Displacement78l
Fuel SystemEUI
Stroke215mm
AspirationDual Turbocharged-Aftercooled
Dimensions
Length6705mm
Height2535mm
Width1986mm
Capacity for Liquids
Lube Oil System - Refill405l
Cooling System - Engine234.7l
Equipment
AIR INLET SYSTEM
Aftercooler core, corrosion resistant (air side)
Air cleaner, regular duty with service indicators
Dual turbochargers, rear mounted
CONTROL SYSTEM
Dual Caterpillar A4 electronic engine control with electronic unit injector fuel system and rigid wiring harness.
24 VDC (less than 10A) to be provided by customer at Power Distribution Panel to power engine electrical system.
COOLING SYSTEM
Jacket water (JW) engine cooling and two-stage jacket water/separate circuit (SCAC) charge air cooling
To ensure compliance in use, radiators or heat exchangers must be capable of rejecting sufficient heat to allow proper engine operation at worst site conditions.
The radiator or heat exchanger must supply 48C (118 F)
SCAC cooling water to the aftercooler inlet of at least 200 gal/min at ambient temperature of 30C and at site conditions (including altitude considerations)
EXHAUST SYSTEM
Dry gas-tight exhaust manifolds with heat shields, dual turbochargers with water-cooled bearings and heat shields.
Exhaust outlet: 305 mm (12 in) round flanged outlet, vertical orientation
FLYWHEELS & FLYWHEEL HOUSINGS
Flywheel, SAE No. 00, 183 teeth Flywheel housing, SAE No. 00
Flywheel housing, SAE No. 00
SAE standard rotation
FUEL SYSTEM
Duplex Fuel filter, LH service. Simplex fuel filter, RH service
Fuel transfer pump
Fuel priming pump, RH
Electronically Controlled Unit Injectors
Customer connection located at lower right front of engine
SOLAS shielding
INSTRUMENTATION
Engine mounted instrument panel with four position switch, over speed shutdown notification light, emergency stop notification light, graphical display unit for analog or digital display of: oil and fuel pressure, oil and fuel filter differential, system DC voltage, exhaust and water temperature, air inlet restriction, service meter, engine speed, fuel consumption (total and instantaneous)
LUBE SYSTEM
Top mounted crankcase breather, RH oil filter, RH oil filler, gear type oil pump, deep sump oil pan, recommended use of Caterpillar Diesel Engine Oil 10W30 or 15W40
MOUNTING SYSTEM
Mounting rails and isolation system based on customer request
ELECTRICAL SYSTEM
MCS certified Class I / Divison 2
Low Smoke Zero Halogen Wiring Harness
PROTECTION SYSTEM
A-III Electronic Monitoring System provides customer programmable engine de-ration strategies to protect against adverse operating conditions
Emergency stop push button (located in Electronic Instrument Panel) Safety shutoff protection for oil pressure and water temperature, over speed protection
HAZARDOUS LOCATION
Only electrical system is hazardous environment certified
NEC 500 Class I Division 2 for gas groups C and D
Temperature class is T3 for ambient temperatures from -10 C to 50 C
Class I/ Division 2 CMPD
GENERATOR AND GENERATOR ATTACHMENTS
Class I / Division 2 designed to customer's specifications
Insulation for harsh environment protection
Benefits & Features
Custom Packaging
Product Support Offered Through the Global Cat Dealer Network
Over 80 Years of Engine Manufacturing Experience
Over 80 Years of Engine Manufacturing Experience
Web Site
Web Site
Documents & Links
-->