The 3516C diesel generator sets have been developed to meet your continuous, standby and prime applications and match your power standards. Producing reliable power from 2250 to 3125 kVA at 50 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and to accept 100 percent rated load in one step. With industry leading innovation our Tier 4 Interim models have emissions reduced up to 90 percent — it's technology that has benefits well beyond todays regulations. Seismic certification is also available for select models, maintaining power after unexpected disturbances. The integrated control system, including ATS and switchgear, ensures a consistent power supply and connection to your fleet through on-site and remote monitoring options. With an user friendly interface our EMCP 4 control panel provides flexible options putting your management and diagnostic tools in one. The EMCP 4.4 controller provides multi-generator set paralleling capability, giving you the ability to add generator sets to provide expanded capacity and generator set redundancy to match your requirements. As no two power requirements are the same we offer a broad range of accessories and bolt-on system expansion attachments. Find flexible packaging options to work with your spatial requirements and environmental conditions. Our 3516C generator sets are developed for such prerequisites, so that you can meet your specific power needs — customize them to match your requirements.

 

Image shown may not reflect actual package.
Enquire
Generator Set Specifications
Minimum Rating2250 kVA
Maximum Rating3125 kVA
Emissions/Fuel StrategyU.S. EPA Cert., Tier 2 - 1808 rpm
Voltage380 to 11000 Volts
Frequency50 Hz
Speed1808 rpm
Duty CycleStandby
Engine Specifications
Engine Model3516C, ATAAC, V-16, 4-Stroke Water-Cooled Diesel
Bore170mm
Stroke215mm
Displacement78.1l
Compression Ratio14.7:1
AspirationATAAC
Fuel SystemElectronic unit injection
Governor TypeAdem™A3
Generator Set Dimensions
Length - Minimum8440mm
Length - Maximum8540mm
Width - Maximum2552mm
Height - Maximum3476mm
Dry Weight - Genset (minimum)20900kg
Dry Weight - Genset (maximum)21600kg
Air Inlet System
Air cleaner; single element canister type
Cooling
Package mounted radiator
Exhaust
Exhaust flange outlet
Fuel
Primary fuel filter with integral water separator
Fuel priming pump
Generator
IP23 Protection
Matched to the performance and output characteristics of Cat engines
Power Termination
Busbar
Control Panel
EMCP 4 Genset Controller
Control System
24 Volt DC operation
EMCP 4.2B
Environmental sealed front face
RFI suppression
Caterpillar' s Voltage Regulato
Emergency stop pushbutton
3 Phase voltage sensing
Generator set packages include:
Text alarm / event descriptions
Generator mounted - rear facing
KVAR / PF modes
IVR includes reactive droop capability
Min / max exciter
Limiter and exciter diode monitor
Speed adjust
Controls:
Engine cycle crank
Auto / start / stop control
Alarm acknowledge
Engine cool
PLC functionality
Load histogram feature
Lamp test
Customizable screens
Digital indication for:
3 Phase
RPM
0 True RMS AC metering
+/- 2% accuracy
DC volts
Operating hours
Coolant temperature
Amps (per phase & average)
Volts (L-L & L-N)
Oil pressure (psi, kPa or bar)
Power Factor (per phase & average
Frequency (Hz)
kVAr (per phase, average & percent)
kVA (per phase, average & percent
kW (per phase, average & percent)
Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -
kVAr-hr (total)
Low oil pressure
kW-hr (total)
Cat Connect
Failure to start (overcrank)
Overcurrent (50/51)
Communications:
Low coolant temperature
Reverse reactive power (kVAr) (32RV)
Low coolant level
6 Customer programmable digital inputs
1 Programmable relay outputs (Form C)
High coolant temperature
4 Programmable relay outputs (Form A)
Programmable protective relaying functions:
Number of I/O varies on options selected:
1 Programmable digital outputs
Serial annunciator module data link
Accessory module data link
Over / under frequency (81 o/u)
Over / under voltage (27/59)
Overspeed
3 Analog inputs
Generator phase sequence
Reverse power (kW) (32)
Governing System
ADEM A3
Cooling System
ATAAC - 3516E Package radiators shipped installed
Certified standard PGS provided
Exhaust System
Dry exhaust manifold
Flanged faced outlet(s)
Fuel System
Flexible fuel lines - shipped loose
Fuel cooler; not included with packages without radiator
Secondary fuel filters
General
Right hand servicing
Paint - Caterpillar Yellow except rails and radiators gloss black
Flywheel and flywheel housing - SAE No. 00
Caterpillar yellow with high gloss black rails and radiator
SAE Standard rotation
Generator and Attachments
Permanent magnet
Low Voltage: Random wound - Internal Excitation - Winding temperature detectors - NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern
Winding temperature detectors
Permanent magnet
Busbar connections, right side extension box, bottom cable entry
6 Lead
Form wound
NEMA standard hole pattern
Medium Voltage:
Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)
High voltage:
Anti condensation space heater
3 Phase brushless, salient pole
Literature
English
Lubrication System
Integral lube oil cool
Gear type lube oil pump
Fumes disposal
Oil drain lines and valve
Oil filter, filler and dipstick
Lubricating oil
Mounting System
Anti-vibration mounts (shipped loose)
Rubber anti-vibration mounts (shipped loose)
Rails - engine / generator / radiator mounting
Starting System
Battery disconnect switch
45 Amp charging alternator
24 Volt electric starting motor
Battery and battery rack w/cables
Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • EU Declaration of Conformity
  • EU Declaration of Incorporation
  • Eurasian Conformity (EAC)
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Specifications
Generator Set Specifications
Minimum Rating2250 kVA
Maximum Rating3125 kVA
Emissions/Fuel StrategyU.S. EPA Cert., Tier 2 - 1808 rpm
Voltage380 to 11000 Volts
Frequency50 Hz
Speed1808 rpm
Duty CycleStandby
Engine Specifications
Engine Model3516C, ATAAC, V-16, 4-Stroke Water-Cooled Diesel
Bore170mm
Stroke215mm
Displacement78.1l
Compression Ratio14.7:1
AspirationATAAC
Fuel SystemElectronic unit injection
Governor TypeAdem™A3
Generator Set Dimensions
Length - Minimum8440mm
Length - Maximum8540mm
Width - Maximum2552mm
Height - Maximum3476mm
Dry Weight - Genset (minimum)20900kg
Dry Weight - Genset (maximum)21600kg
Equipment
Air Inlet System
Air cleaner; single element canister type
Cooling
Package mounted radiator
Exhaust
Exhaust flange outlet
Fuel
Primary fuel filter with integral water separator
Fuel priming pump
Generator
IP23 Protection
Matched to the performance and output characteristics of Cat engines
Power Termination
Busbar
Control Panel
EMCP 4 Genset Controller
Control System
24 Volt DC operation
EMCP 4.2B
Environmental sealed front face
RFI suppression
Caterpillar' s Voltage Regulato
Emergency stop pushbutton
3 Phase voltage sensing
Generator set packages include:
Text alarm / event descriptions
Generator mounted - rear facing
KVAR / PF modes
IVR includes reactive droop capability
Min / max exciter
Limiter and exciter diode monitor
Speed adjust
Controls:
Engine cycle crank
Auto / start / stop control
Alarm acknowledge
Engine cool
PLC functionality
Load histogram feature
Lamp test
Customizable screens
Digital indication for:
3 Phase
RPM
0 True RMS AC metering
+/- 2% accuracy
DC volts
Operating hours
Coolant temperature
Amps (per phase & average)
Volts (L-L & L-N)
Oil pressure (psi, kPa or bar)
Power Factor (per phase & average
Frequency (Hz)
kVAr (per phase, average & percent)
kVA (per phase, average & percent
kW (per phase, average & percent)
Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -
kVAr-hr (total)
Low oil pressure
kW-hr (total)
Cat Connect
Failure to start (overcrank)
Overcurrent (50/51)
Communications:
Low coolant temperature
Reverse reactive power (kVAr) (32RV)
Low coolant level
6 Customer programmable digital inputs
1 Programmable relay outputs (Form C)
High coolant temperature
4 Programmable relay outputs (Form A)
Programmable protective relaying functions:
Number of I/O varies on options selected:
1 Programmable digital outputs
Serial annunciator module data link
Accessory module data link
Over / under frequency (81 o/u)
Over / under voltage (27/59)
Overspeed
3 Analog inputs
Generator phase sequence
Reverse power (kW) (32)
Governing System
ADEM A3
Cooling System
ATAAC - 3516E Package radiators shipped installed
Certified standard PGS provided
Exhaust System
Dry exhaust manifold
Flanged faced outlet(s)
Fuel System
Flexible fuel lines - shipped loose
Fuel cooler; not included with packages without radiator
Secondary fuel filters
General
Right hand servicing
Paint - Caterpillar Yellow except rails and radiators gloss black
Flywheel and flywheel housing - SAE No. 00
Caterpillar yellow with high gloss black rails and radiator
SAE Standard rotation
Generator and Attachments
Permanent magnet
Low Voltage: Random wound - Internal Excitation - Winding temperature detectors - NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern
Winding temperature detectors
Permanent magnet
Busbar connections, right side extension box, bottom cable entry
6 Lead
Form wound
NEMA standard hole pattern
Medium Voltage:
Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)
High voltage:
Anti condensation space heater
3 Phase brushless, salient pole
Literature
English
Lubrication System
Integral lube oil cool
Gear type lube oil pump
Fumes disposal
Oil drain lines and valve
Oil filter, filler and dipstick
Lubricating oil
Mounting System
Anti-vibration mounts (shipped loose)
Rubber anti-vibration mounts (shipped loose)
Rails - engine / generator / radiator mounting
Starting System
Battery disconnect switch
45 Amp charging alternator
24 Volt electric starting motor
Battery and battery rack w/cables
Benefits & Features
Cat Generator Set Package
Cat Diesel Engine
SR5 Alternator
EMCP 4 Control Panel
Cooling System
Certifications
One Safe Source
World Wide Product Support
-->